Graphical User Interface for A Risk Assessment Against Lightning Protection System in Malaysia
Keywords:
Malaysian Standard, Graphical User Interface (GUI)Abstract
This paper presents the general risk assessment calculations based in Malaysian Standard, Protection against lightning-Part 2 (MS IEC 62305-2:2007) using MATHLAB - Graphical User Interface (GUI). A GUI application was developed to calculate the general risk assessment concerned and compare it with the tolerable risk. All parameters’ values and calculation techniques used in (MS IEC 62305-2:2007) are available to the user. The parameter value used to calculate the risk assessment was guided in the program. This paper also provides the capability to evaluate new risk assessment after selecting the appropriate class of lightning protection system. The selection of the protection level would result in reducing the risk assessment, thus protecting the structure, power line and telecommunication lines.